What this code means
On a Whirlpool oven, FEE6 concerns the main cavity bake element. The control switched the bake element on and did not get the result it expected back, and the documented meaning names the element together with the wiring that reaches it.
Error codes
Reference| Code | Meaning |
|---|---|
| FEE6 | There may be a problem with the main cavity bake element or the associated wiring. |
What the appliance is doing
- The oven never comes up to temperature on bake — It may preheat forever without signalling ready, or heat only weakly from above.
- The rest of the appliance behaves normally — Controls respond, the cycle starts, and only the function that depends on this heat is wrong.
- The cavity smells of nothing and stays cold where it should be hot — A dead heating load gives no smell, no noise and no warmth.
- NEAR MISS — the oven heats but browns unevenly — Uneven browning with no code is a fan, a rack position or a calibration matter.
What triggers this code, in order
- The element has failed open — Ranked first because it is the part the code names and because this is how elements end.
- A terminal or connector on the heating circuit has burned or loosened — These circuits carry the highest current in the appliance, so a terminal that is merely loose runs hot, oxidises and then opens.
- The safety device in series with the load has opened — Heating circuits run through thermal cut-outs and fuses that open on over-temperature and often do not reset.
- The control or relay that switches the load has failed — Last: a stuck or dead relay produces the same result as a dead element, but it is the least likely of the four and the one that costs the most to guess at.
The check order this code implies
- Confirm which functions heat and which do not — Try bake, then broil, then a convection setting if the oven has one.
- Look for visible damage on the load itself — With the oven cold and the power off, look at the load itself where it is visible in the cavity.
- Measure the load and its circuit at the control — Continuity through the load and through each safety device in series with it, then the switched feed.
Owner-safe checks, step by step
- Cut power at the breaker for a full minute, then restore it — This clears the stored code and lets any thermal device that opened on over-temperature cool.
About 5 min
- Check the breaker at the panel, including both halves — A heating appliance on a double-pole breaker can lose one leg and keep its controls.
About 10 min
- Look over the visible heating elements with the oven cold — Power off at the breaker. Look along the whole run of each element for a break, a blister or a burned spot, and check where it passes through the rear wall.
Tools: torchAbout 15 min
- STOP HERE if the next step needs a meter on live terminals or a panel off — That is the line between an owner check and a service call on this circuit.
Safety first
Safety
Unplug the oven or switch off its breaker before any panel comes off. A capacitor can hold a charge after the power is off, and a built-in oven is normally hard-wired, so the breaker is its only disconnect. If your range burns gas and you smell gas: leave the building without switching anything on or off, call the gas utility or emergency services from outside, and do not look for the leak yourself.
When this is a service call
Call once power has been cycled, the breaker is confirmed good and the fault repeats.
Nearby codes on the same appliance
Scope of this page
This page reads FEE6 as Whirlpool documents it for ovens in this range, so it covers the appliance class rather than one model line: a wall oven, a range and a microwave-oven combination can all post it with different hardware behind the panel. Where a family- or model-specific page exists for your unit it is the more specific answer, and it is linked from the code index below.
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.