What you are actually seeing
- Interior light works but nothing ever runs
- A click every few minutes and no run
- Not this fault: It runs constantly and will not get cold
Ranked causes on a Contoure refrigerator
- Converter, inverter or battery supply not delivering — Ranked here because: a coach appliance can be fed from shore power, a generator, an inverter or the battery bank, and a supply that is present but weak produces faults that look like component failures
- Outlet dead, on a switch, on a GFCI or on a tripped breaker — Ranked here because: the converter and the transfer switch sit between the appliance and whatever is actually powering it, and both fail in ways that look like a dead machine
- Supply cord, plug or extension lead faulty — Ranked here because: a coach installation is tighter than any domestic one and the venting and clearance shortcuts taken during the build show up as faults later
- Start relay or overload protector failed — Ranked here because: this is a wear part with a service life rather than a component that fails at random
What to check, and in what order
- Check the breaker panel and any GFCI outlet on the same circuit, including in a garage or outdoors
- Plug the cabinet directly into a known-good outlet with no extension lead
- Leave the cabinet plugged in and untouched for fifteen minutes and listen
- Turn the cold control or setpoint through its whole range and listen for a click
Steps you can safely do yourself
- Leave the cabinet plugged in and untouched for fifteen minutes and listen — Tools: none — Estimated time: about a quarter of an hour
- Turn the cold control or setpoint through its whole range and listen for a click — Tools: none — Estimated time: a few minutes
- Stand at the back of the cabinet and listen for a repeated click every few minutes — Tools: none — Estimated time: about ten minutes
- Plug a lamp into the same outlet and confirm it lights — Tools: lamp or outlet tester — Estimated time: a few minutes
- Check the breaker panel and any GFCI outlet on the same circuit, including in a garage or outdoors — Tools: none — Estimated time: a few minutes
Safety
Safety
unplug-before-service branch-circuit-15-20a
When to call a technician
the compressor clicks on its overload without starting, which is a start-component or compressor diagnosis there is a burnt smell, a hot plug or a discoloured outlet the supply is confirmed good, the control calls for cooling, and nothing runs
Nearest pages
What this page does not cover
Not this fault: the family pages for the refrigeration, cooking and laundry lines Not this fault: model-specific pages once the model and serial label is read
Links: - [Common CONTOURE Refrigerator Problems](/blog/contoure-refrigerator-problems) - [Common CONTOURE Dryer Problems](/blog/contoure-dryer-problems) - [Common Contoure Microwave Problems](/blog/contoure-microwave-problems) - [CONTOURE Refrigerator: Abnormal Noise or Vibration](/blog/contoure-refrigerator-abnormal-noise)
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.