What you are actually seeing
- A solid block of ice in the mould that never releases
- Small, hollow or half-formed cubes
- Ice with an odour or a taste
- Not this fault: No ice and a freezer that is not properly cold
Ranked causes on a Contoure refrigerator
- Water supply closed, kinked or at low pressure — Ranked here because: a coach installation is tighter than any domestic one and the venting and clearance shortcuts taken during the build show up as faults later
- Fill tube frozen — Ranked here because: a door latch and gasket that has been slammed by road motion is a routine finding
- Ice maker switched off or the feeler arm lifted — Ranked here because: coach appliances are used intermittently and stored for months, which produces its own fault pattern
- Water filter past its life or not seated — Ranked here because: a restriction builds gradually, so performance falls off long before anything stops
What to check, and in what order
- Put a thermometer in the freezer and read it after an hour
- Dispense water for ten seconds and judge the flow, or check the mould for a recent fill
- Change the water filter and purge several litres through the dispenser
- Empty the bin and look at the fill tube outlet at the back of the freezer for a plug of ice
Steps you can safely do yourself
- Change the water filter and purge several litres through the dispenser — Tools: replacement filter — Estimated time: about a quarter of an hour
- Empty the bin and look at the fill tube outlet at the back of the freezer for a plug of ice — Tools: flashlight — Estimated time: a few minutes
- Empty the bin completely, check for a wedged cube at the ejector and refit the bin fully — Tools: none — Estimated time: about ten minutes
- Confirm the ice maker is switched on and the feeler arm is down and free to move — Tools: none — Estimated time: a couple of minutes
- Put a thermometer in the freezer and read it after an hour — Tools: appliance thermometer — Estimated time: about an hour
Safety
Safety
unplug-before-service freezer-0f
When to call a technician
the mould fills and freezes but the harvest never turns, which is a module replacement the inlet valve or the supply line needs work behind the cabinet the freezer will not reach its temperature, since that is a cooling fault and not an ice one
Nearest pages
What this page does not cover
Not this fault: the family pages for the refrigeration, cooking and laundry lines Not this fault: model-specific pages once the model and serial label is read
Links: - [Common CONTOURE Refrigerator Problems](/blog/contoure-refrigerator-problems) - [Common CONTOURE Dryer Problems](/blog/contoure-dryer-problems) - [Common Contoure Microwave Problems](/blog/contoure-microwave-problems) - [CONTOURE Refrigerator: Abnormal Noise or Vibration](/blog/contoure-refrigerator-abnormal-noise)
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.