The short answer
This is the profile page for the Commercial Cool CCR refrigerator line. twenty-six model numbers share the CCR designation. They are in the table below, and the trailing letters that separate them are finish and trim codes rather than different mechanisms — the fault below behaves the same across the list. Below are the faults that actually bring a technician out to these cabinets, in the order they arrive, each linked to the page that covers it.
What goes wrong on these models, and where to read about it
- Water inside the cabinet or on the floor — The cheapest fault on this list and the most damaging if ignored — almost always the defrost drain. — Slug: commercial-cool-commercial-cool-refrigerator-ccr-refrigerator-water-leak — Title: Commercial Cool CCR Refrigerator: Water Leak
- Warm inside while the unit runs — Airflow first: a dusty condenser and a tight installation account for most of these before any part is suspected. — Slug: commercial-cool-commercial-cool-refrigerator-ccr-refrigerator-cooling-failure — Title: Commercial Cool CCR Refrigerator: Not Cooling or Not Freezing
- No ice, or poor ice — Only on the models with a maker. Check it is switched on and the compartment is cold before anything is ordered. — Slug: commercial-cool-commercial-cool-refrigerator-ccr-refrigerator-ice-production — Title: Commercial Cool CCR Refrigerator: Ice Maker Fault
- Buzzing, rattling or ticking — Locate it first: back, inside or underneath. Each one means something different and only one is urgent. — Slug: commercial-cool-commercial-cool-refrigerator-ccr-refrigerator-abnormal-noise — Title: Commercial Cool CCR Refrigerator: Abnormal Noise or Vibration
What brings a technician out to these cabinets
- Heat that cannot leave the cabinet — The dominant fault class on these models: a condenser blinded by dust, or an installation with no clearance behind and above.
- Defrost water that cannot drain — Second. The drain is one small hole, it blocks, and the water then appears inside the cabinet or on the floor.
- Warm air that gets in past the seal — Third, and often behind both of the above: it warms the cabinet and builds the frost that blocks the air path.
- Everything else, including the sealed system — Last. Fans, relays, sealed-system faults and ice makers together account for less than the first three.
Models in the CCR family
Reference| Model number | Family key |
|---|---|
| CCR16* | commercial-cool:refrigerator:ccr |
| CCR16W | commercial-cool:refrigerator:ccr |
| CCR1800GB | commercial-cool:refrigerator:ccr |
| CCR1800GIMB | commercial-cool:refrigerator:ccr |
| CCR1800GIMS | commercial-cool:refrigerator:ccr |
| CCR1800GIMW | commercial-cool:refrigerator:ccr |
| CCR1800GS | commercial-cool:refrigerator:ccr |
| CCR1800GW | commercial-cool:refrigerator:ccr |
| CCR2000GB | commercial-cool:refrigerator:ccr |
| CCR2000GIMB | commercial-cool:refrigerator:ccr |
| CCR2000GIMS | commercial-cool:refrigerator:ccr |
| CCR2000GIMW | commercial-cool:refrigerator:ccr |
| CCR2000GS | commercial-cool:refrigerator:ccr |
| CCR2000GW | commercial-cool:refrigerator:ccr |
| CCR26* | commercial-cool:refrigerator:ccr |
| CCR26B | commercial-cool:refrigerator:ccr |
| CCR26W | commercial-cool:refrigerator:ccr |
| CCR32* | commercial-cool:refrigerator:ccr |
| CCR32B | commercial-cool:refrigerator:ccr |
| CCR32W | commercial-cool:refrigerator:ccr |
| CCR40WBR | commercial-cool:refrigerator:ccr |
| CCR45* | commercial-cool:refrigerator:ccr |
| CCR45W | commercial-cool:refrigerator:ccr |
| CCR77LBB | commercial-cool:refrigerator:ccr |
| CCR77LBS | commercial-cool:refrigerator:ccr |
| CCR77LWW | commercial-cool:refrigerator:ccr |
Fault profile for this family — ranked, not measured — No warehouse sample covers this family, so this profile is ordinal: it ranks the problem classes by how often they bring a technician out to an appliance of this class. It carries no measured share and no denominator.
General guidance| Problem class | How often it is the cause |
|---|---|
| Cooling loss — airflow and condenser | Most common on this cabinet class |
| Defrost drain leaks | Second, and cheapest to fix |
| Noise and vibration | Common as a complaint, rarely a failure |
| Ice production | Only on models fitted with a maker |
| Sealed system and compressor | Least common, and the costliest |
Where the owner line is on these models
On these cabinets the owner line sits at the back panel. Condenser cleaning, clearance, levelling, the door seal, the defrost drain, the drip tray, the load and the settings are all yours, and they account for most faults on this list. Behind the panel — fan motors, defrost components, the start relay and the sealed system — is service work on a live appliance, and on a cabinet of this size a sealed-system fault is usually where the repair-or-replace conversation ends. The twenty-six models listed share this diagnosis but not their part numbers, so have the rating plate to hand before the visit is booked.
Other Commercial Cool refrigerator families
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.