Straight answer first
When a Comfee CERR refrigerator gets loud, sort the normal sounds from the abnormal ones before deciding anything is wrong. A compact unit cannot soak up what its compressor produces, which is why placement matters so much here. The steps below place the sound first and only then ask whether the part making it is faulty.
What the owner sees and hears
- A rhythmic scrape in time with the fan — A fan blade touching ice or a shroud produces a rhythmic scrape, and it gets worse as the ice grows.
- Clicking with no compressor start — Note the interval — a few minutes between clicks is the classic pattern.
- Ticking as the cabinet cools or warms — Brief and irregular sounds are almost always thermal.
- Liquid sounds from inside the walls — It happens at shutdown because the loop is relaxing, so it is healthy rather than faulty.
- NEAR MISS — water noise with a puddle — Audible dripping with water on the floor is a drainage fault, and that has its own page.
Ranked causes for these models
- Drip tray loose or out of position — It ranks here because the fix is reseating a part by hand, and the noise is a classic rear rattle.
- The unit coupled to the floor — First on this family because these cabinets are low-mass and their feet are all that separates them from the floor.
- A circulation or condenser fan touching something — A fan that has become rough is telling you it will stop soon.
- Contact with a wall, worktop or neighbouring unit — A cabinet wedged into an alcove shares every vibration with the structure around it.
What to check first, second, third
- Check the condensate pan sits square on its rails — Seat it firmly and check it cannot shift when you nudge it.
- Start with how the unit stands — All four feet must bear; a cabinet that moves under your hand is not level.
- Look for a blade touching a shroud — A rhythmic scrape once per revolution is something catching, not a bearing.
- Move everything off and away from the cabinet — Second because items on top buzz louder than anything inside.
- Test each panel for drumming — Replace a fastener that is gone and check the cover sits flat.
Safety first, and it is not optional
Safety
Locate noise by touch on the OUTSIDE of the cabinet while it runs, and open nothing until the power is off. Isolate the machine before any cover comes off — the starting components sit right there. Do not bend or lever refrigerant tubing to gain clearance: a nicked line turns a rattle into a sealed-system repair.
Models in the CERR refrigerator family
Reference| Model number | Family key |
|---|---|
| CERR16B0A** | comfee:refrigerator:cerr |
| CERR33B0A** | comfee:refrigerator:cerr |
When this stops being a DIY job
Noise plus a cabinet that is no longer cooling is a cooling call, not a noise call. Call if the machine clicks and will not run — that is a starting-circuit or compressor fault.
The rest of this family
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.