What this usually means
On the Aviva ADBI dishwasher line, leaks that follow a cycle and leaks that are there all the time are different faults. A constant drip is a supply-side fitting under mains pressure; a leak that appears only during a wash is the door, the tub or the drain path. What changes against the brand-generic answer is the order of the checks, not the list of causes.
The observations that matter on a ADBI unit
- A slow drip behind the machine that never stops — Supply side, under mains pressure, and it is there whether the appliance runs or not. This is what an owner of a ADBI dishwasher sees first.
- Foam escaping around the door during the cycle — Overfoaming rather than a seal failure, and the cause is in the dispenser rather than in the appliance.
- Water only on one side of the machine — Useful: it points at a specific hose run rather than at the door, which leaks centrally.
- The leak appeared the week something else was fitted nearby — A waste connection or a supply tee disturbed during other work is a common origin.
- NEAR MISS: water is coming from the sink waste rather than the appliance — Worth eliminating first, because a shared cabinet hides which of the two is wet.
What it usually turns out to be on the ADBI line
- A tired or dirty door gasket — Ranked first because it is both the most common and the easiest to confirm: grease and food residue on the seal stop it compressing, and the leak shows at the front centre of the door. The ADBI build does not move this one: its rank is the same here as on the brand-generic page.
- Overfoaming from the wrong detergent or too much of it — Second, and the one that is almost never suspected. Washing-up liquid in the dispenser will put foam on the floor from an appliance with nothing wrong with it.
- A loose hose clip or a perished hose behind the machine — Third. Clips loosen over years of heat cycling, and the hose run gets crushed when the machine is pushed back into its housing.
- A split tub or a failed pump seal — Last, because it is the least likely and the only one that is not owner-checkable. It is diagnosed once everything above is clean.
The order that narrows it
- Establish whether the water is clean or soapy — Clean water is the fill side; soapy water has been through the wash. One touch, and half the list goes. The ADBI layout is the reason it comes first here.
- Watch a cycle through the glass or listen at the door for foam — Foam escaping is an entirely different fault from water escaping, and the fix is in the dispenser.
- Check the hose clips at the inlet and the drain connections — Hand-snug, and look for the white mineral trail that a slow leak leaves behind.
- Look for standing water in the tub before the cycle starts — A drainage fault forcing water out elsewhere is a real cause of a floor leak.
Before you open anything
Safety
Isolate the appliance and dry the floor before starting. Put towels down before a hose is disconnected: a drain hose holds water along its whole length and empties the moment it is freed.
Models in the ADBI family
Reference| Model number | Family key |
|---|---|
| ADBI245SS | aviva:dishwasher:adbi |
Where the owner side ends
Stop and call when the leak is clean water and constant: that is mains pressure behind it, and a weeping inlet valve does not improve on its own. Shut the supply valve while you wait.
The nearest pages for the ADBI line
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.