Start here
When an MT unit stops cooling, the useful split is whether it makes no cold at all or makes cold it cannot distribute. The door does more work on a compact cabinet than on any full-size refrigerator, so it is checked before anything internal, and that distinction decides everything that follows. Start with a door or lid that is not sealing and leave a loss of refrigerant charge until everything cheaper has been excluded.
The observables
- It runs for a few minutes, stops, and starts again — The same short cycle repeated all day, with the cabinet never coming down.
- Cold at the plate, warm at the far end of the cabinet — Cooling is being made but not distributed, which points at air rather than at the system.
- A hum or a click every few minutes and no sustained run — Something attempts to start and drops out, and the machinery end never warms.
- The panel is lit and nothing ever starts — The electronics are alive but no cooling is ever called for.
- NEAR MISS - cold enough but noisy — Noise with normal temperatures is a mounting or contact problem, not a cooling problem, and it has its own page.
Causes, most likely first on this line
- A door or lid that is not sealing — The leading cause on these models: a gasket that has taken a set, a door held ajar by contents, or a hinge that has dropped lets the cabinet exchange air continuously. The compressor never stops and the cabinet never gets down, so it reads as a cooling failure.
- A frosted plate blocking airflow — Second: the frost is a consequence of humid air getting in, so this cause usually sits downstream of a seal or a door problem and returns if only the ice is dealt with.
- The condenser unable to shed heat — Third, and worth excluding before going further: a condenser boxed in, dusty or pressed against a wall cannot give up heat, so the compressor runs and runs and the cabinet never reaches temperature. The unit looks healthy and performs like a broken one.
- A loss of refrigerant charge — It ranks last deliberately: every cause above it produces the same warm cabinet for a fraction of the cost.
The order to work in
- Test the seal at several points — Close the door on a strip of paper at the top, the middle and the bottom of each side and pull. Anywhere it slides out freely is a leak, and the coldest part of the cabinet will be furthest from it.
- Look at the plate before concluding anything — Note where the frost is heaviest, since that is where the warm air is arriving.
- Give the condenser air and a clean grille — Pull the unit a hand-width clear on every side, brush the grille and the coil clean with the unit isolated, and give it a few hours. A cabinet that recovers had a heat problem.
Before any panel comes off
Safety
Unplug the appliance or switch off its breaker before removing any panel - a capacitor can hold a charge after the power is off. Do not defeat a door switch to keep the cabinet running with the door open while you test; use a thermometer instead.
Models in the MT family
Reference| Model number | Family key |
|---|---|
| MT25 | alpicool:refrigerator:mt |
| MT35 | alpicool:refrigerator:mt |
When this stops being owner work
Everything reachable without a panel is owner work. Repeated failed starts, a fan motor, a sensor disagreement or anything on the sealed system is not, because those need measurement and refrigerant work is licensed work.