The short answer
The G line is quiet by design, which is why a change is noticed early on the models listed in the table on this page. That early notice is an advantage: ice contact caught as a tick is a defrost problem solved before it becomes a temperature problem.
The symptoms, and their near misses
- A low drone from the back of the cabinet — Condenser fan or compressor. The drone rises and falls with the compressor cycle and is loudest standing behind the machine.
- A rattle that changes when the cabinet is pushed — If a hand on the panel changes the sound, the sound is a panel. Check the rear cover and the pan first. On these models the panel comes away before anything else does.
- A gurgle or trickle from inside the cabinet — Refrigerant moving through the evaporator. It is normal, it is louder on some cabinets than others, and it needs nothing done.
- A ticking or scraping that stops when the freezer door opens — The door switch cuts the evaporator fan, so a noise that dies with the door open is that fan and nothing else.
- The noise appears only with the doors shut — Doors-shut-only noise is the interior fan by definition.
- NEAR MISS — the noise came with a warming cabinet — A warm cabinet outranks any sound. Start on the cooling page for this appliance.
- NEAR MISS — the noise is from the ice bin, not the machine — Cubes dropping and the auger turning are loud and entirely normal, especially on a bin that is nearly empty.
The ranking that matters
- A genuinely failing compressor — First — and it is not close. Last, and it is rare. It sounds like a hard metallic knock on start, the cabinet warms afterwards, and it is not an owner repair under any circumstances. It is one of the few places the models listed in the table on this page genuinely diverge.
- Thermal expansion of the interior liner — Next most likely. The liner moves as the cabinet cycles and clicks against its fixings. It is normal and there is nothing to repair.
- An unlevel cabinet or an uneven floor — Next after those two. Compressor torque has to go somewhere. On an unlevel cabinet it goes into a knock, and the fix is a spanner on the front feet. It is worth knowing that the models listed in the table on this page share this layout.
- A failing evaporator fan motor — Less common than the three above. A motor on the way out whines or grinds continuously while the door is closed. The door test locates it; only a full defrost separates it from ice.
- The water inlet valve buzzing on each fill — Near the bottom of the list. A valve energising against low pressure or a closed tap hums loudly for the length of the fill. Turning the ice maker off for a day is the definitive test.
The order to check in
- Switch the ice maker off for a day — A one-day test that eliminates the entire water side of the machine.
- Empty the freezer and look for frost at the rear panel — Frost distribution decides between ice contact and a failing motor — the two sound similar and cost very differently. On the models listed in the table on this page this is the check that decides the job.
- Note whether the noise is present at start-up only — The timing within the cycle is as informative as the location.
- Clear the condenser coil and listen again — A choked coil makes the rear fan work harder and louder; cleaning it sometimes removes the noise outright.
Read this before you start
Safety
Switch the circuit off before you start, not after. A capacitor can hold a charge after the power is off, so give it a moment before working in the machine compartment. Interior door switches are part of the safety design of the cabinet and should be left wired as they are.
Models in the G family
Reference| Model number | Family key |
|---|---|
| G91626NEW | beko:refrigerator:g |
| G91629NEW | beko:refrigerator:g |
| G91661NE | beko:refrigerator:g |
| G91711NE | beko:refrigerator:g |
When this becomes a service call
The urgent version of this fault is a metallic knock followed by a cabinet that stops getting cold. Book that one immediately; everything else on this page can wait for a convenient appointment.
Nearest pages of this class
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.