The short answer
When a cabinet from the RA family stops holding temperature while the compressor still cycles, the cold is either not being made where it should be or not being carried to where it is needed. When one of these units stops holding temperature the machine usually keeps running, and that is the single most useful clue on the page: a unit that runs and stays warm has a heat-removal problem, not a power problem.
What you observe on these models
- The interior light is on and the fan is silent — Where a model has a fan behind the rear panel, silence from it with the door held open is a strong pointer, though door switches complicate the test on some cabinets.
- The compressor runs and never cycles off — A unit that never reaches its setpoint never satisfies its control, so it simply keeps going. Long run times are a symptom of the fault, not a second fault.
- It cools better when it is nearly empty — A unit that copes until it is loaded is running out of capacity rather than failing outright, and that points at airflow and at the seal before it points at the compressor.
- NEAR MISS - the unit is silent and nothing is cold — No hum at all is a supply, start-relay or control fault rather than a cooling one, and it belongs on the noise page or with a technician.
Causes, most likely first on this platform
- The door seal and how the door sits — A seal that no longer seals is a heat load that never goes away, and a cabinet fighting one will run forever without arriving. Gaskets go hard, hinges drop, and a cabinet standing out of level stops pulling its own door shut. Across a group this wide the machines share little but the door, and the gasket ages at the same rate whichever base you own.
- The fan or the cold control — Second on this platform. A dead fan or a control that has drifted stays on the list, but it is worth reaching only once the free checks are clean, since confirming either needs a panel off.
- Airflow blocked by a frosted evaporator — Third here. Ice that has closed the airflow path produces exactly this complaint, and it stays on the list until somebody has looked at the cold surface instead of at the dial.
- Dust on the coil and a wall too close behind — Fourth. A blanketed coil costs capacity rather than removing it, which is why it shows up as a cabinet that manages in winter and gives up in the first warm week.
- The one fault on this list that is not owner work — Last. Last, and last for a reason: refrigerant work is licensed work, the tools are not owner tools, and the four causes above account for most cabinets that arrive with this complaint.
Check in this order, and why
- Close the door on a sheet of paper and pull — Do it at several points around the frame. Anywhere the paper slides out without resistance is a gap, and a gap anywhere is a permanent load on the cold system. With 28 entries on 14 bases in the table below, this check is one of the few that means the same thing across all of them.
- Look at the cold surface for frost — You are looking for the difference between a dusting and a skin. A skin means airflow, and airflow explains a warm cabinet with a working compressor better than anything else does.
- Listen for the fan with the door held open — Where the model has one, the fan should be audible once the door switch is defeated by the handle rather than by you. Silence with the compressor running narrows it hard.
Before you open anything
Safety
Isolate the machine at the plug or the breaker before any panel comes off, and expect a capacitor to hold a charge after the power has gone. Do not chip frost off a cold surface with a knife or a screwdriver: the tubing behind it is thin, and a puncture turns a cheap fault into a scrapped cabinet. Refrigerant work is licensed work and the tools for it are not owner tools.
Models in the RA family
Reference| Model number | Family key |
|---|---|
| RA10X0W-IS | avanti:refrigerator:ra |
| RA10X1B-IS | avanti:refrigerator:ra |
| RA10X3S-IS | avanti:refrigerator:ra |
| RA3106WT | avanti:refrigerator:ra |
| RA3116BT | avanti:refrigerator:ra |
| RA3136SST | avanti:refrigerator:ra |
| RA31B** | avanti:refrigerator:ra |
| RA31B0W | avanti:refrigerator:ra |
| RA31B1B | avanti:refrigerator:ra |
| RA31B3S | avanti:refrigerator:ra |
| RA32J0W | avanti:refrigerator:ra |
| RA32J1B | avanti:refrigerator:ra |
| RA32J3S | avanti:refrigerator:ra |
| RA45B3S | avanti:refrigerator:ra |
| RA7306WT | avanti:refrigerator:ra |
| RA7306WT-IS | avanti:refrigerator:ra |
| RA730B0W | avanti:refrigerator:ra |
| RA7316PST | avanti:refrigerator:ra |
| RA7316PST-IS | avanti:refrigerator:ra |
| RA731B1B | avanti:refrigerator:ra |
| RA7326BT | avanti:refrigerator:ra |
| RA7326BT-IS | avanti:refrigerator:ra |
| RA733B3S | avanti:refrigerator:ra |
| RA75**** | avanti:refrigerator:ra |
| RA75V** | avanti:refrigerator:ra |
| RA75V0W | avanti:refrigerator:ra |
| RA75V1B | avanti:refrigerator:ra |
| RA75V3S | avanti:refrigerator:ra |
When to call a technician
The line is the panel. Anything you can reach with the door open - the setting, the seal, the loading, the clearance - is yours; anything behind the rear panel or on the sealed system is not. Call straight away if the compressor is hot and silent, if a breaker trips when it tries to start, or if there is oil where there should not be, and do not keep cycling the power to see whether it catches this time.