Start here
Two different complaints arrive under this heading on the Alpicool BD refrigerator: too little ice, on models that make it, and too much ice, on models that do not. The six codes in this family share the BD prefix and differ only in what follows it, running from BD45 to BD135. Decide which of the two you have before reading any further, because the causes below are ranked for both and they have almost nothing in common.
The observables on these models
- The maker runs its cycle and nothing comes out — Noise on schedule, an empty mould: the machine is being asked and has nothing to work with.
- Production stopped after the cabinet was moved or cleaned — The two events that most often leave a valve shut, an arm lifted or a control switched off.
- Cubes are hollow, small, or stuck together in a lump — A mould that is not cold enough, or ice that has been sitting long enough to fuse.
- NEAR MISS — the cabinet is also failing to hold temperature — Then this is a cooling fault first. Work the cooling page for this family; the ice is a symptom of it.
Ranked causes for these models
- Damp air getting in and freezing where it lands — First. Where the complaint is too much ice rather than too little, the source is almost always air. Every opening, and every hour a seal does not grip, brings moisture that freezes on the coldest plate — which is why the build-up is always thickest nearest the cold and nearest the leak. The same check covers everything from BD45 to BD135; the record gives no reason to treat those codes differently here.
- A setpoint colder than the job needs — Second. Set to its limit, the cabinet runs longer and holds the plate colder, and everything that drifts in ends up frozen to it. It is the most common self-inflicted version of this complaint and it is undone at the panel.
- A compartment that is not cold enough to harvest — Last. Ice will not leave a mould that is not properly cold, so a compartment running warm produces slow ice, hollow ice, or none. That makes this a cooling fault presenting as an ice fault, and it is worth ruling out before anything is blamed on the maker.
- Body: Six codes, one BD prefix, BD45 at one end and BD135 at the other. What the trailing block of each code measures is not recorded here, so treat the models as one platform unless the part in front of you plainly differs. Nothing in the record says a code in this family carries an ice maker, and on cabinets of this kind the complaint that actually arrives is unwanted ice rather than absent ice — so air ingress leads and the maker-side causes sit below it.
The order to work in
- Test the seal and count the openings — A strip of paper round the seal finds the leak path; a lid that gets opened every few minutes in a warm room needs no fault at all to ice up. Identical on every code from BD45 to BD135.
- Bring the setting back to what the job needs — Then give it a day. Ice already formed will not retreat on its own — it has to be thawed out once before the new setting can be judged.
- Body: Nothing in the record separates these codes by arrangement, so the same three checks apply to all of them, ordered by what each one rules out. Do them in this order: each step is only meaningful once the one above it is clean.
Before any panel comes off
Safety
Unplug the cabinet or switch off its breaker before working behind it; a capacitor can hold a charge after the power is off. Where a water line is involved, shut the supply valve before disturbing any fitting, and dry the floor afterwards: meltwater from a thaw finds sockets and extension leads.
Models this page covers — The six model codes recorded for this family; the record carries no column separating them.
Reference| Model number | Family key |
|---|---|
| BD110 | alpicool:refrigerator:bd |
| BD135 | alpicool:refrigerator:bd |
| BD45 | alpicool:refrigerator:bd |
| BD60 | alpicool:refrigerator:bd |
| BD75 | alpicool:refrigerator:bd |
| BD85 | alpicool:refrigerator:bd |
Where owner work stops
Thawing, clearing a drain, correcting a setpoint and reseating a seal are all owner work, and between them they end most of these calls. It becomes a service call when the cabinet ices up again quickly with all of those right, when a plumbed line leaks at the fitting, or when the compartment cannot be brought cold enough to harvest at all — that last one is a cooling fault and is urgent in a way the ice is not.
Other faults covered for this family
Lead Appliance Repair Technician · 12 years experience
Experienced technician with 12 years specializing in washing machine and dryer repairs across all major brands.