Humidity sensor error

Locate the humidity sensor bars inside the dryer drum — they are two metal strips mounted on the front bulkhead that clothes contact during tumbling
Clean the sensor bars with a cloth dampened with rubbing alcohol to remove dryer sheet film and fabric softener residue — this is the most common cause of HS on LG dryers
If cleaning does not resolve the error, check the sensor wire connections at the front bulkhead — vibration can loosen the spade connectors
Test sensor bar resistance — when dry, resistance between the bars should be open (infinite); when touched with damp cloth, resistance should drop to under 100k ohms
If the sensor tests OK, the main board ADC input for the humidity sensor may have failed
Pro Diagnostic Tip
Fabric softener and dryer sheets leave a waxy film on the humidity sensor bars over time. This film insulates the bars from moisture contact, making the dryer think clothes are dry when they are still damp. Switch to liquid fabric softener in the wash cycle instead of dryer sheets to reduce buildup.
Repair Difficulty
Moderate — Some Experience NeededEstimated Repair Cost
$80–$200
Parts + labor. Free diagnosis with repair.
Parts That May Need Replacement
Gas leak detector ($130), thermal fuse tester ($95), belt tension gauge, and vent inspection camera ($180). Our technician arrives with $15K+ in professional tools — your diagnostic is free.
Licensed & Insured · 90-Day Warranty · Same-Day Service
Gas dryers carry carbon monoxide and explosion risk. Even electric dryers involve 240V circuits that can deliver a fatal shock. Our techs are licensed and insured — let them handle the risk.
Licensed & Insured · 90-Day Warranty · Same-Day Service
Don't let error code HS disrupt your day. A professional diagnosis takes about 30 minutes — and it's free when you proceed with the repair.
Licensed & Insured · 90-Day Warranty · Same-Day Appointments Available
Fixed or It's Free
$89 → $0 Service Call & Diagnosis — offer ends May 31
LG error code HS indicates: Humidity sensor error. This is a medium-severity issue affecting your dryer.
Locate the humidity sensor bars inside the dryer drum — they are two metal strips mounted on the front bulkhead that clothes contact during tumbling Then, Clean the sensor bars with a cloth dampened with rubbing alcohol to remove dryer sheet film and fabric softener residue — this is the most common cause of HS on LG dryers Then, If cleaning does not resolve the error, check the sensor wire connections at the front bulkhead — vibration can loosen the spade connectors There are 2 more steps — see the full troubleshooting guide above. This repair typically requires professional tools and expertise.
Besides the error code on the display, common signs include: Clothes still damp when cycle ends on auto-dry; Dryer running much longer than expected on auto-dry; Auto-dry cycle ending after only a few minutes. If you notice any of these symptoms, check your dryer's display panel for error code HS.
Repair costs for LG HS typically range from $80 to $200 depending on the specific cause and parts needed. EasyBear offers free diagnosis when you proceed with the repair. Call (415) 795-7300 for a same-day appointment.