What this GE vs Kenmore comparison is based on#
Two federal complaint records are counted on this page: 265 CPSC SaferProducts incident reports naming a component on a GE refrigerator between 2011 and 2026, and 373 doing the same for a Kenmore refrigerator between 2011 and 2025. Every share is a share of its own column's total. Neither total counts refrigerators sold or in service, and no rate can be derived from either.
One record has a single subject#
The GE column is the most lopsided in this comparison set. The ice maker takes 24% of its reports — 64 filings out of 265 — and no other component reaches 3%. Its second place is the control board at 2%, six filings, and its third is the compressor at 2%, five filings.
That is not a profile in the usual sense. It is one large row followed by a tail in which every entry is between one and six reports, which is the region where a share stops describing a component and starts describing a handful of submissions.
The Kenmore column is built differently. Its compressor row is 11%, 42 filings; its ice maker row is 9%, 35 filings; its control board row is 7%, 25 filings. Three components carry meaningful weight, and each one is supported by enough reports to survive a few reclassifications.
The two headline gaps run in opposite directions#
The ice maker separates the records by 15 points, 24% against 9%, and that gap is carried by 64 GE filings against 35 Kenmore ones. It is the largest difference here and the one built on the most reports.
The compressor runs the other way by 9 points, 2% against 11%. This one deserves the more careful reading, because the GE side of it is five filings. A share of 2% in a record of 265 is a small count, and the honest statement is that the GE reports in this window rarely named the compressor — not that GE compressors rarely fail.
The control board follows the same direction at 5 points, 2% against 7%, and the same caution applies: six GE filings against 25 Kenmore ones.
What the flat GE tail probably means#
A record can be flat below its leading row for two reasons that look identical in a table. Either the other components genuinely draw few complaints, or the complaints exist but describe symptoms rather than parts, in which case they land in no component row at all.
Nothing on this page distinguishes those two cases, and the second is the more common. What can be said is narrower: among GE filings that did name a part, the ice maker dominates so completely that everything else is a handful. Among Kenmore filings that named a part, the naming spreads across three components.
Where the two columns simply agree#
Below the headline rows the records converge. The wiring or power cord is a point apart, 2% against 3%. The motor is a point apart, 1% against 2%. The condenser, the evaporator and the thermostat or sensor sit at 1% on both sides, and the water valve or line at 0% on both — one filing each. The table marks four of those as showing no measured difference, and they should be read as agreement.
GE's tail also carries two single-filing curiosities, a drive belt and a heating element, that are best understood as the edge of the classification rather than as refrigerator parts worth planning around.
Two windows that do not quite match#
The GE reports run through 2026 and the Kenmore ones stop in 2025, so the Kenmore column is missing its most recent submissions. Over fifteen years that is a small asymmetry, but it is another reason to treat one-point differences as noise rather than as findings.
Why the two columns are not equally useful#
It is tempting to treat a comparison as symmetric — two records, two columns, one verdict. This pairing is a good argument against that habit, because the two columns support very different amounts of weight.
The Kenmore column can be read as a ranking. Its first three rows are 42, 35 and 25 filings, and the distances between them are larger than the distances a handful of reclassified reports could produce. Someone asking what Kenmore refrigerator complaints are about has a genuine three-item answer.
The GE column can be read as one statement and then a shrug. Its top row is 64 filings and its second is six. The gap between first and second place is not a ranking, it is a cliff, and below the cliff there is nothing to rank. Someone asking what GE refrigerator complaints are about has a one-item answer and no honest second.
That asymmetry is worth naming because it changes what the comparison rows mean. When GE's compressor sits 9 points below Kenmore's, the Kenmore side of that gap is a measured feature of its record and the GE side is five reports. The gap is real as arithmetic; it is not two comparable measurements of the same thing.
Reading the pair together#
For a technician the two columns give different amounts of help. On a GE, the record points hard at the ice maker and then goes quiet. On a Kenmore, it points at the compressor, the ice maker and the control board in that order, and all three are worth carrying into a diagnosis. Neither column ranks the brands, because neither counts refrigerators.
GE vs Kenmore refrigerators: what the reports mention#
Both columns are shares of their own corpus, and the corpora differ in size. GE: CPSC SaferProducts incident reports for GE refrigerators, 2011-2026, n=265. Kenmore: CPSC SaferProducts incident reports for Kenmore refrigerators, 2011-2025, n=373. A difference no larger than one report on either side is marked "within one-report noise".
| Component mentioned | GE | Kenmore | Difference |
|---|---|---|---|
| Ice Maker | 24% (64 of 265) | 9% (35 of 373) | 15 points more often for GE |
| Compressor | 2% (5 of 265) | 11% (42 of 373) | 9 points more often for Kenmore |
| Control Board | 2% (6 of 265) | 7% (25 of 373) | 5 points more often for Kenmore |
| Motor | 1% (2 of 265) | 2% (8 of 373) | 1 point more often for Kenmore |
| Wiring or Power Cord | 2% (4 of 265) | 3% (12 of 373) | 1 point more often for Kenmore |
| Condenser | 1% (3 of 265) | 1% (2 of 373) | no measured difference (within one-report noise) |
| Evaporator | 1% (3 of 265) | 1% (2 of 373) | no measured difference (within one-report noise) |
| Thermostat or Sensor | 1% (3 of 265) | 1% (5 of 373) | no measured difference (within one-report noise) |
| Water Valve or Line | 0% (1 of 265) | 0% (1 of 373) | no measured difference (within one-report noise) |
About the corpus: these are CPSC SaferProducts reports — incidents someone chose to report, not units sold — so the shares on this page are shares of the reports and never a failure rate. The corpus is weighted toward safety events: 12,007 of its 20,581 records (58%) are fire, smoke, burn or melt reports, which over-represents the components that burn and under-represents the ones that merely stop working.
Do You Have the Right Tools?
Refrigerant gauges ($200+), vacuum pump ($250), leak detector ($150), and EPA-certified recovery equipment. Our technician arrives with $3,000+ in professional tools — your diagnostic is free.
Licensed & Insured · 90-Day Warranty · Same-Day Service
GE refrigerators: the reported component split#
GE refrigerators — every share in this table is a share of: CPSC SaferProducts incident reports for GE refrigerators, 2011-2026, n=265.
| Component mentioned | Share of reports | Reports |
|---|---|---|
| Ice Maker | 24% | 64 of 265 |
| Control Board | 2% | 6 of 265 |
| Compressor | 2% | 5 of 265 |
| Wiring or Power Cord | 2% | 4 of 265 |
| Condenser | 1% | 3 of 265 |
| Evaporator | 1% | 3 of 265 |
| Thermostat or Sensor | 1% | 3 of 265 |
| Motor | 1% | 2 of 265 |
| Drive Belt | 0% | 1 of 265 |
| Heating Element | 0% | 1 of 265 |
| Water Valve or Line | 0% | 1 of 265 |
Shares of reports, not failure rates — see the corpus note above.
Kenmore refrigerators: the reported component split#
Kenmore refrigerators — every share in this table is a share of: CPSC SaferProducts incident reports for Kenmore refrigerators, 2011-2025, n=373.
| Component mentioned | Share of reports | Reports |
|---|---|---|
| Compressor | 11% | 42 of 373 |
| Ice Maker | 9% | 35 of 373 |
| Control Board | 7% | 25 of 373 |
| Wiring or Power Cord | 3% | 12 of 373 |
| Motor | 2% | 8 of 373 |
| Thermostat or Sensor | 1% | 5 of 373 |
| Condenser | 1% | 2 of 373 |
| Evaporator | 1% | 2 of 373 |
| Defrost System | 0% | 1 of 373 |
| Water Valve or Line | 0% | 1 of 373 |
Shares of reports, not failure rates — see the corpus note above.
Safety First — Know the Risks
Refrigerant (R-134a/R-600a) requires EPA certification to handle. Improper discharge is a federal violation and health hazard. Our techs are licensed and insured — let them handle the risk.
Licensed & Insured · 90-Day Warranty · Same-Day Service
How to use these numbers#
What this comparison can settle: which components the reported incidents of each brand actually concentrate on, for this appliance. What it cannot settle: which brand fails more often. That would need units sold, and no public source states it. Use the component split to plan for the repair each brand is most reported for, not to rank the two.
Senior Appliance Repair Technician · 15 years experience
EPA-certified technician with 15 years of experience specializing in refrigerator and cooling system repairs.

