FAE5 explained
Maytag's code list gives FAE5 a potential cause of a diverter leak. When water escapes inside the cabinet, where and when it shows up outside is useful evidence: a drip that appears during the wash, a puddle under the door after the drain, or a wet patch at one corner each point a professional toward a different part of the plumbing. Switch the dishwasher off and dry the floor. Then, before the repair, note where any water appears so the leak can be found quickly.
Error codes
Reference| Code | Meaning |
|---|---|
| FAE5 | Potential Cause: Diverter Leak |
Where the water shows
- Under the centre of the door — Water collected in the base often runs out at the front.
- At one front corner — A leak on one side of the tub can track to that corner.
- Only during the wash phase — Leaks under pump pressure appear while the arms are spraying.
- Only after the drain — Water at the end of a cycle can point to the drain path instead.
- No water outside, only the code — The leak may still be contained in the base.
Ranked causes of FAE5
- A leaking diverter seal — First: the seal that should hold water at the valve wears out.
- Excess suds — Second: foam escapes past seals and gaskets.
- A cracked diverter housing — Third: it weeps on every cycle.
- A nearby hose or clamp — Fourth: water from another joint ends up in the same place.
Reading the evidence
- Switch off and dry the floor completely — Start from a dry floor so new water is easy to spot.
- Lay a dry towel along the front — It shows exactly where water appears.
- Note the stage of the cycle — Fill, wash or drain.
- Check for suds — Foam changes the likely cause.
- Photograph what you find — Pictures help the professional start in the right place.
- Wipe the door edge dry — A wet door seal can hide where the water really comes from, so dry it before the test.
Owner steps for FAE5
- Cut the power, then towel the floor — Work from the toe kick outward until the floor is dry.
Tools: towelsAbout 10 min
- Let the base dry overnight — Keep the power off.
Tools: ::
- Lay a dry towel along the toe kick — It marks where any new water appears.
Tools: towelAbout 2 min
- Start a brief rinse with the towel in place — Note when and where it gets wet, then switch off.
About 20 min
- Arrange the repair — A professional reaches the seal or housing from underneath, with the supply and the electrics isolated.
Tools: ::
Water and power safety
Electricity and water share the space under the tub, so isolate the dishwasher at its breaker before you mop close to it. Watch the rinse from in front of the dishwasher, without reaching underneath, and switch off at once if water spreads. Never bypass the door switch. Keep the kick panel fitted, since components behind it may retain charge. Dry floors promptly to prevent slips.
When FAE5 needs a professional
Arrange a repair when FAE5 comes back once the base is dry and the foam is gone, or whenever water finds its way onto the floor a second time. Tell the professional where the water appeared and at which stage; that points them straight to the diverter seal, its housing or the nearby joints. A photo of the towel after the test rinse is a quick way to show the pattern.
Other diverter and leak codes
Which dishwashers this applies to
Maytag built-in dishwashers whose code list includes FAE5 are what this page addresses. Other Maytag appliances and other brands fall outside it. A page for an individual model has not been written; base and tub designs differ, so consult your model's documentation.